Comm-Tec EIB Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Bramy / kontrolery Comm-Tec EIB. Comm-Tec EIB User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 22
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
- 1 -
User Manual
for the
COMM-TEC EIB Gateway
CTG-KNX/IP (v1.0.1)
Przeglądanie stron 0
1 2 3 4 5 6 ... 21 22

Podsumowanie treści

Strona 1 - User Manual

- 1 -User Manualfor theCOMM-TEC EIB GatewayCTG-KNX/IP (v1.0.1)

Strona 2 - Table of contents

- 10 -Command DescriptionEIS5? <No> Inquiry EIS5 valueConverts the 2Byte raw data into ASCII string with floating pointNote: Only valid for actu

Strona 3 - 1 Introduction

- 11 -3.3.2 Feedback from moduleThe feedback is always in STRING format.The module can generate the following feedback:StringDescriptionDATE=<No>

Strona 4 - NetLinx Master

- 12 -Command DescriptionADR_<Value> Definition of output format of EIB group address(Main/medium/sub group OR main group/sub group)<Value>

Strona 5

- 13 -Command DescriptionLIST_<No>-<No2> List actuators in the range of <No> to <Nr2> (AMX numbers) with EIB group address,cur

Strona 6 - 2 Hardware

- 14 -3.3.4 Channels and levelsAll addresses are available as channels. The current value is displayed on the corresponding channels of thevirtual dev

Strona 7 - 3 Programming

- 15 -5 Appendix A – Sample program5.1 Notes EIB tableAll actuators to be switched/set/controlled are to be introduced to the gateway. This is achieve

Strona 8

- 16 -5.2.1 Example 1 – Structure of EIB table with functions from EIB_Tools.AXIStart delay, module reports ready for ADDStartSet light 1Set light 2Se

Strona 9

- 17 -5.2.2 Example 2 - Structure of EIB table with SEND_COMMANDSStart delay, module reports ready for ADDStartSet light 1Set light 2Set light 3Light

Strona 10 - Command Description

- 18 -5.2.3 Example 3 – Enter addresses from fileThe address table can be read and generated from file on CF card. The reading of the file can for ins

Strona 11 - Description

- 19 -5.2.4 Example 4 – Main programfeedback array for max 3000 addressesLight 1 ONAnalog actuator 50%Dimmer brighterfeedback for light 1 (see EIB tab

Strona 12

- 2 -Table of contents1 Introduction...

Strona 13

- 20 -6 Appendix B – EIB_Tools.AXIWe recommend not to use the send commands directly, but always utilize the functions of this include file. Thecompil

Strona 14 - 4 Data Types

- 21 -7 Appendix C – Comparison with previous versionThe general operation of hardware and software has not changed. A filter table has still to be ge

Strona 15 - 5 Appendix A – Sample program

- 22 -8 Appendix D – What to do if it does not work?The following table provides tips for error definition, in case it does not work.This serves a qui

Strona 16

- 3 -1 Introduction1.1 AimsThe software module is being used to connect AVIT and AMX control systems to the "EuropeanInstallation Bus" EIB (

Strona 17

- 4 -Figure 1 – Process of CommunicationNetLinx MasterEIBGatewayNetLinxModuleNetLinxProgramVirtualDevice

Strona 18

- 5 -1.4 EIB details when using the GatewayIn principle, the EIB gateway CTG-KNX/IP is a normal EIB device, and can therefore be connected atany locat

Strona 19

- 6 -2 Hardware2.1 Interfaces, Indication and Operating DevicesConnections :230 V EIBRJ45LEDs : Busspannung flashes when bus voltage drops below 15V

Strona 20 - 6 Appendix B – EIB_Tools.AXI

- 7 -3 Programming3.1 Integrating the ModuleAt first, the program needs to get the information, what the Gateway’s IP-Address is.This can be done by t

Strona 21 - 7.3 Feedback

- 8 -on an „AMX number between 1 and 3000. Communication with the actuators concerned is only madevia this number.This tabel is integrated with the fo

Strona 22

- 9 -3.3 The NetLinx module interface3.3.1 Commands for moduleCommands to the module always take place per SEND_COMMAND to the virtual device.The modu

Komentarze do niniejszej Instrukcji

Brak uwag